Vai al contenuto

Cambridge International A-Level Biology

A-Level · Cambridge International (CAIE)Biology49 appunti in 20 cartelle, 280 KB

49 note di ripasso per Cambridge International (CAIE) A-Level Biology, create da cookie, in 20 sezioni che seguono gli argomenti del corso.

Notes for Cambridge International AS & A Level Biology (9700), in folders for each of the syllabus's twenty topic areas in its order, with the practical investigations in the topics they belong to. A last folder covers planning, analysing and evaluating investigations. Delete the folders your course leaves out if you take AS only (the first eleven topics are the AS content).

Aggiungendole, ne verrà copiata una versione nelle tue note, in una cartella dedicata con le cartelle qui sotto. Potrai modificarle e trasformarle in flashcard o in un mazzo di domande. Scaricandole otterrai un file zip con file markdown, che si aprono in qualsiasi app per prendere appunti.

Contenuto

  • Cell structure
    • Microscopy and magnification7 KB
    • Eukaryotic cells, prokaryotic cells and viruses7 KB
  • Biological molecules
    • Carbohydrates7 KB
    • Lipids and water5 KB
    • Proteins5 KB
  • Enzymes
    • How enzymes work6 KB
    • Factors affecting enzyme activity7 KB
  • Cell membranes and transport
    • Membrane structure and cell signalling6 KB
    • Movement across membranes8 KB
  • The mitotic cell cycle
    • Chromosomes, the cell cycle and mitosis6 KB
  • Nucleic acids and protein synthesis
    • Nucleic acids and DNA replication5 KB
    • Transcription, translation and mutation6 KB
  • Transport in plants
    • Xylem, phloem and the movement of water8 KB
    • Translocation in phloem4 KB
  • Transport in mammals
    • Blood vessels, blood and tissue fluid7 KB
    • Transport of oxygen and carbon dioxide5 KB
    • The heart and the cardiac cycle5 KB
  • Gas exchange
    • The human gas exchange system4 KB
  • Infectious diseases
    • Cholera, malaria, TB and HIV7 KB
    • Antibiotics and resistance4 KB
  • Immunity
    • The immune response5 KB
    • Antibodies, monoclonal antibodies and vaccination6 KB
  • Energy and respiration
    • ATP, respiratory substrates and RQ6 KB
    • Glycolysis, the link reaction and the Krebs cycle4 KB
    • Oxidative phosphorylation and anaerobic respiration6 KB
  • Photosynthesis
    • Chloroplasts and pigments5 KB
    • The light-dependent stage5 KB
    • The Calvin cycle and limiting factors6 KB
  • Homeostasis
    • Homeostasis, the kidney and osmoregulation8 KB
    • Blood glucose control and cell signalling5 KB
    • Homeostasis in plants3 KB
  • Control and coordination
    • Neurones and action potentials7 KB
    • Synapses and striated muscle8 KB
    • Coordination in plants4 KB
  • Inheritance
    • Meiosis5 KB
    • Genetic crosses5 KB
    • Linkage, epistasis and the chi-squared test5 KB
    • Genes, proteins and gene control6 KB
  • Selection and evolution
    • Variation and the t-test4 KB
    • Natural selection, drift and Hardy-Weinberg5 KB
    • Selective breeding, evolution and speciation5 KB
  • Classification, biodiversity and conservation
    • Classification5 KB
    • Biodiversity and sampling7 KB
    • Conservation7 KB
  • Genetic technology
    • Recombinant DNA and gene editing5 KB
    • PCR, electrophoresis, microarrays and databases5 KB
    • Genetic technology in medicine and agriculture6 KB
  • Practical skills
    • Planning investigations6 KB
    • Processing data and evaluating results8 KB

La prima nota

Cell structure / Microscopy and magnification

Units of length

Cells and their contents are measured in three units, each a thousand times smaller than the one before.

UnitSymbolSize
millimetremm10−310^{-3} m
micrometreµm10−610^{-6} m, so 1 mm = 1000 µm
nanometrenm10−910^{-9} m, so 1 µm = 1000 nm

A typical animal cell is tens of micrometres across, a bacterium is one to five micrometres, a ribosome is around 25 nanometres and a virus is tens to hundreds of nanometres. Choosing the unit that gives a number between about 1 and 1000 keeps calculations manageable, and converting between units is the commonest place to lose a factor of a thousand.

Magnification and resolution

Magnification is how many times larger an image is than the real object. Resolution is the smallest distance between two points at which they can still be seen as separate. A microscope that magnifies without resolving more detail only makes a blurred image larger, which is why the two ideas are kept apart: magnification can be increased without limit on paper, but resolution is set by the wavelength of the radiation used.

A light microscope uses visible light, whose wavelengths (roughly 400 to 700 nm) limit resolution to about 200 nm (0.2 µm). Two structures closer together than that merge into one blob, however high the magnification. Useful magnification therefore stops at about ×1500. Electron microscopes use a beam of electrons, whose wavelength is far shorter, so they resolve structures much less than a nanometre apart in the best transmission instruments and a few nanometres apart in scanning instruments.

Light and electron microscopes compared

FeatureLight microscopeTransmission electron microscopeScanning electron microscope
Radiationvisible lightelectron beam passing through a very thin sectionelectron beam scanned over the surface
Resolutionabout 200 nmhighest, well under 1 nmlower than TEM, a few nanometres
Imagetwo-dimensional, in colour if stainedtwo-dimensional, black and white, internal detailthree-dimensional appearance of the surface
Specimencan be living, thin or thin-sectioneddead, dehydrated, cut into very thin sections and stained with heavy metal saltsdead, dehydrated and coated with a thin layer of metal
Seennucleus, large organelles, cell outlinesorganelle ultrastructure such as cristae, ribosomes, membranessurface shape of cells, tissues and organisms

Electron microscopes work in a vacuum, because air would scatter the electrons, and this is why their specimens cannot be alive. The preparation (fixing, dehydrating, staining or coating) can produce artefacts, which are structures in the image that were not present in the living cell, so an electron micrograph is interpreted with that in mind.

Preparing a temporary slide

A temporary preparation of plant or animal tissue is made to be looked at straight away and thrown away afterwards.

  1. Cut or peel a very thin piece of tissue, such as onion epidermis or a slice of a leaf, so that light can pass through a single layer of cells.
  2. Place it on a clean slide in a drop of water, or in a drop of stain. Iodine in potassium iodide solution stains starch grains blue-black and makes plant nuclei easier to see; methylene blue stains the nuclei of cheek cells.
  3. Lower a coverslip onto the specimen at an angle, using a mounted needle, so that air bubbles are not trapped. Air bubbles look like dark rings and hide the cells.
  4. Blot away any liquid at the edge, then view under low power first and move up to a higher power.

Drawing what is seen

A drawing of cells from a slide is made with clear single pencil lines, with no shading and no colouring. It is large enough to show the detail, it shows only what is seen (not what a textbook says should be there), and each label line touches the structure it names without crossing other lines. A plan diagram, used for tissues, shows the outlines and distribution of tissues and draws no individual cells.

Measuring with an eyepiece graticule

An eyepiece graticule is a small scale in the eyepiece lens, marked in arbitrary divisions. Its divisions have no fixed size, because the image it is laid over changes with the objective lens in use. It is calibrated against a stage micrometer, a slide with a scale of known length, usually divided into 10 µm intervals.

  1. Put the stage micrometer on the stage and focus on it with the objective lens that will be used.
  2. Rotate the eyepiece so that the two scales lie side by side, and line up the zero marks.
  3. Find a place further along where the two scales line up exactly again, and count the divisions of each.
  4. Work out the length of one eyepiece division.

For example, if 50 eyepiece divisions line up with 20 stage divisions of 10 µm each, then 50 eyepiece divisions equal 200 µm, so

1 eyepiece division=200 μm50=4 μm1\text{ eyepiece division} = \frac{200\ \mu\text{m}}{50} = 4\ \mu\text{m}

A cell that spans 12.5 eyepiece divisions is 12.5×4=50 μm12.5 \times 4 = 50\ \mu\text{m} long. The calibration belongs to one objective lens, so it is repeated whenever the lens is changed. Measuring several cells and taking a mean reduces the effect of variation between cells.

Calculating magnification and actual size

The relationship between the three quantities is

magnification=size of imageactual size of object\text{magnification} = \frac{\text{size of image}}{\text{actual size of object}}

and it is rearranged to find whichever quantity is missing. The image and the object must be in the same unit before dividing, and since actual sizes are usually in micrometres, the measured image length in millimetres is converted to micrometres first.

Worked example: magnification from a drawing

A student draws a cell and measures the drawing as 54 mm long. The cell is known to be 18 µm long.

54 mm=54 000 μmmagnification=54 00018=×3000 \begin{aligned} 54\ \text{mm} &= 54\,000\ \mu\text{m} \\ \text{magnification} &= \frac{54\,000}{18} = \times 3000 \end{aligned}
Worked example: actual size from a micrograph

An electron micrograph of a mitochondrion has magnification ×14 000. The mitochondrion measures 63 mm on the printed image.

actual size=image sizemagnification=63 mm14 000=0.0045 mm=4.5 μm \text{actual size} = \frac{\text{image size}}{\text{magnification}} = \frac{63\ \text{mm}}{14\,000} = 0.0045\ \text{mm} = 4.5\ \mu\text{m}
Using a scale bar

Many micrographs carry a scale bar instead of a stated magnification. The bar is measured with a ruler, and its length on the page is divided by the length it is labelled with. If a bar labelled 2 µm measures 30 mm, then

magnification=30 000 μm2 μm=×15 000\text{magnification} = \frac{30\,000\ \mu\text{m}}{2\ \mu\text{m}} = \times 15\,000

and any other structure in the same image is then measured in the same way and divided by 15 000 to give its real size. A scale bar stays correct if the picture is copied at a different size, whereas a stated magnification does not.

E altre 48 dopo averle aggiunte o scaricate.

Valutazioni

Non ci sono ancora recensioni scritte. Aggiungi queste note alle tue e potrai essere il primo a lasciarne una.