A primeira anotação

Practical skills and data analysis / Planning and evaluating experiments

Variables in a fair test

Every experiment has an independent variable, which the experimenter chooses and changes, and a dependent variable, which is measured as a result. Everything else that could affect the dependent variable is a control variable, and it has to be kept constant. A test is fair when the only thing that changes the result is the independent variable. If a control variable is allowed to drift, the pattern in the results cannot be attributed to the change you made, so the conclusion is weakened.

Take a pendulum investigation into how the period depends on length. The length is the independent variable, the period is the dependent variable, and the mass of the bob, the release angle (kept small, below about 10 degrees) and the way the pendulum is released are all controlled. Writing the plan this way before any apparatus is set up is the first skill the course asks for, because it forces the experimenter to name each variable and say how it will be held constant.

Choosing the method

A good method is one that can produce the data the question needs. For a pendulum the period is short and hard to time by eye, so the method should measure many oscillations at once. Timing 20 swings and dividing the total by 20 reduces the relative effect of the timer's start and stop errors. Suppose each start or stop is judged to about 0.2 s. On a single swing of period 2.01 s that is an error of about 10%, since 0.2/2.01≈0.09950.2 / 2.01 \approx 0.0995. On the total of 40.2 s for 20 swings it is about 0.5%, since 0.2/40.2≈0.0050.2 / 40.2 \approx 0.005. The same timer gives a far better period when it is spread over many swings, which is why the method says so.

Other techniques reduce error in the same way. A fiducial marker, a fixed point that the bob passes through at the lowest point, means every reading is taken from the same place. A set square or plumb line keeps a length measured at right angles, or along the true vertical. A light gate removes the human reaction time entirely when it can be used.

Recording and analysing

Every measurement needs a unit, and the table should give the unit in the heading, not beside each number. Repeat each reading and take a mean, because the mean smooths out random error. Plot the results so that a relationship can be tested. For the pendulum, T=2πLgT = 2\pi\sqrt{\dfrac{L}{g}}, so T2=4π2gLT^{2} = \dfrac{4\pi^{2}}{g}L. A graph of T2T^{2} against LL is therefore a straight line through the origin with gradient 4π2g\dfrac{4\pi^{2}}{g}. If the best-fit gradient is 4.02 s2 m−14.02\ \mathrm{s^{2}\,m^{-1}}, then g=4π24.02≈9.8 m s−2g = \dfrac{4\pi^{2}}{4.02} \approx 9.8\ \mathrm{m\,s^{-2}}, which matches the accepted value of the gravitational field strength at the Earth's surface.

Axes should be labelled with the quantity and its unit, and the scale should spread the points across most of the grid. The line of best fit goes through the middle of the points, not through the first and last point.

Apparatus, techniques and research in the practical endorsement

Practical work builds a set of instrument skills that are used again and again. An analogue scale, such as a ruler or a micrometer, is read by estimating between its markings. A digital multimeter measures current, potential difference and resistance, and it must be connected correctly: an ammeter goes in series with the component and a voltmeter in parallel with it. An oscilloscope, used with a signal generator, shows the shape of an electrical wave, and its time-base and volts-per-division settings give the period and amplitude. Light gates and data loggers record times and readings automatically, and software can then process the data.

Research is part of the same skill set. Information is found in textbooks, printed scientific sources and reliable websites, and every source used is cited, so that a reader can find the original.

Evaluating the result

An evaluation says how far the result can be trusted and what to change. Look first for anomalous readings, those clearly outside the spread of the others, and check them before deciding whether to keep them. Then separate the two kinds of error. Random error makes readings scatter, and repeats and a mean reduce it. Systematic error shifts every reading in the same direction, as a zero error on a ruler does, and repeats do not reduce it, so it must be found and corrected.

A good suggested improvement names the largest source of uncertainty and then changes that. If the timer's reaction time dominates, the answer is a light gate. If the length is uncertain because the bob's centre is hard to locate, the answer is a clearer marker on the bob. Saying what would be improved, and why it would make a difference, is what turns a list of errors into an evaluation.

E mais 18: abra qualquer um deles na lista acima.

Avaliações

Ainda não há avaliações escritas. Adicione estas notas às suas e você poderá ser a primeira pessoa a deixar uma avaliação.